Indoor Air Quality: Why Ventilation Alone Isn’t Enough
The temperature in the office may be comfortable, yet people still feel tired after an hour-long meeting. In a retail space, the HVAC system may run according to a preset schedule without responding to the actual occupancy of the space. Indoor environmental quality is therefore not just a matter of an open window or a set temperature. It is the result of a combination of measurements, operating mode, and specific conditions within the building.
Thanks to smart technologies, it is possible to monitor how the environment changes throughout the day, in different rooms, and with varying numbers of people. The measured data help identify recurring situations, evaluate the effectiveness of ventilation, and better plan technical measures. It is important to understand what a specific value means—and, conversely, what it does not reveal on its own.
Why Ventilation Alone Isn’t Enough
Ventilation brings in outdoor air and removes some of the pollutants generated indoors. However, the required air volume is not the same throughout the day. A meeting room for ten people behaves differently during a short meeting than it does during a three-hour session. Similarly, the conditions vary in studios, offices with fluctuating occupancy, or retail spaces during peak hours.
Opening a window once may help, but it may not ensure stable conditions. In addition, outdoor temperature, noise, dust, and energy consumption fluctuate. For spaces with mechanical ventilation, it is also necessary to evaluate the HVAC settings, air supply and exhaust, filters, and operating schedules. The purpose of these measurements is not to replace a professional assessment of the system, but to provide concrete data to support it.
CO₂, temperature, and humidity: three different pieces of information
One of the most commonly monitored indicators is the concentration of carbon dioxide (CO₂). In normally occupied indoor spaces, changes in CO₂ levels can serve as a useful indirect indicator of whether the amount of fresh air being supplied corresponds to the occupancy level. However, CO₂ is not a universal measure of all pollutants, nor is it, on its own, proof that a space is safe for health.
Temperature is an indicator of thermal comfort, but it must be evaluated in conjunction with airflow, solar gain, human activity, and the type of space. Relative humidity, in turn, affects perceived comfort and can signal an environment that requires further investigation. For some buildings, it is also important to monitor particulate matter or other pollutants if there is a specific reason to do so.
| Indicator | What helps determine | What to Watch Out For |
| CO₂ | Changes in Ventilation in Relation to the Presence of People | It does not describe all pollutants |
| Temperature | Thermal conditions in a specific room | The price alone doesn’t capture the full extent of the comfort |
| Relative humidity | Changes in Humidity Conditions | The result also depends on temperature and local sources of moisture |
| Occupancy | The Relationship Between the Use of Space and Changing Values | It requires proper interpretation and an appropriate measurement method |
| Status of the Ventilation System | The Relationship Between Equipment Operation and Environmental Quality | An operational signal does not replace a service inspection |
A single value isn’t enough. What matters is the trend throughout the day.
Let’s imagine a conference room where we measure normal levels in the morning. As participants arrive, the CO₂ level begins to rise. After the meeting ends, the levels gradually return to their initial state. It is precisely this trend that can help determine whether ventilation is sufficient given the actual occupancy, or whether there is a recurring need to adjust the ventilation settings.
The situation is different when a similar pattern occurs even when the room is empty. In that case, it is advisable to check the sensor’s location, its calibration, the available occupancy data, and the technical condition of the system. A meaningful evaluation therefore begins with the question of what was happening in the room at that particular moment.
Where Air Quality Monitoring Is Used in Practice
Offices and conference rooms. Fluctuating occupancy levels create varying air exchange requirements. A long-term overview helps identify which rooms experience recurring deterioration in air quality and when it occurs.
Studios and creative workspaces. In addition to comfort, stable conditions over time may be important. Depending on the nature of the work, it is also necessary to take into account specific sources of pollution that a standard CO₂ sensor cannot detect.
Business Units. The number of visitors varies throughout the day. Comparing the available environmental data with operating hours and equipment operation can reveal whether the current ventilation system is adequate.
Technical and auxiliary spaces. Temperature stability, humidity, or the operating status of the equipment may be decisive factors here. Requirements are determined based on the purpose of the space and the technical documentation, not on a universal setting for the entire building.
From the sensor to clear data in the app
A separate display on the wall shows the current value. However, for long-term work with a facility, it is much more useful to know which room the data comes from, how it has changed over time, and whether it is related to a specific operating mode. That is why it is important to link the measurements to a digital inventory of spaces and technologies.
INTECHI works with smart technologies and operational data in the context of real-world facilities. An overview of the indoor environment can be supplemented with information about specific rooms, equipment, and related operational events. The specific available features and the degree of integration always depend on the installed technologies and the configuration of the building in question.
This approach builds on the principle described in the article What kinds of things can a smart device know about its surroundings?: Data itself only gains real value when considered in relation to place, time, and a specific situation.
When Are Alerts and Automation Useful?
Monitoring can detect a recurring deviation, but this does not necessarily mean that the HVAC system controls need to be adjusted. In some buildings, it is more appropriate to notify the person in charge, who will then investigate the cause. In other cases, following a professional assessment and safe configuration, the data can be used to adjust the operating mode.
An example of this is a recurring increase in CO₂ levels in a particular room when it is occupied. The next step does not necessarily have to be an immediate increase in fan speed: first, it is necessary to verify the accuracy of the measurements, the condition of the ventilation system, and the actual needs of the occupants. Only then does it make sense to consider adjusting the settings or scheduling a service call.
What to Consider When Selecting and Placing Sensors
A sensor located right next to a window, door, air vent, or heat source may display readings that do not reflect typical conditions in the occupied zone. The specific device’s features, measurement method, calibration, power supply, and reliable data transmission are also important.
When designing a system, it is therefore advisable to first determine which operational question the measurements are intended to answer. Otherwise, the organization may end up with dozens of graphs but no usable basis for decision-making. The design should also include a method for evaluating the data and clarify who is responsible for the subsequent response.
How to Integrate Environmental Quality with Technical Operations
A long-term overview is most valuable when it is not separated from the documentation and maintenance requirements. In INTECHI Client Portal It is possible to work with information about objects, equipment, documentation, and operational requirements. Depending on the specific integration, data from smart technologies can then form an additional related layer.
For example, if a problem occurs repeatedly in a single room, simply viewing the graph isn’t enough. It’s important to identify the relevant equipment, review its service history and any documentation, and determine the next steps. Connecting people, spaces, and processes is more useful than having several separate applications.
FAQ: Frequently Asked Questions About Air Quality
Is a single CO₂ sensor enough to assess air quality?
No. CO₂ is a useful indicator related to ventilation and occupancy, but it does not capture all pollutants. Depending on the purpose of the building, other parameters and expert assessment may also be important.
Does a high CO₂ level always indicate a problem with the ventilation system?
Not necessarily. It could be related to high occupancy, operating settings, sensor placement, or other factors. The cause needs to be investigated in context.
Is it worth measuring indoor air quality even in a small office?
Yes, if the measurement addresses a specific issue, such as recurring problems with conditions during meetings. The scope of the system should correspond to the need for space, not its size.
Does smart monitoring have to automatically control ventilation?
It doesn’t have to. The overview itself and timely alerts may be sufficient benefits. Automated control is a separate step that requires appropriate technologies, design, and verification of safe operation.
Is it possible to link the measurements to the equipment and request records?
Yes, provided that the chosen technical architecture and application configuration allow for it. The goal is for the information from the room to be linked to a specific device, document, or operational task.
How INTECHI Handles It
INTECHI integrates the technical operations of buildings with smart technologies and digital environments. For offices, studios, and commercial spaces, we help place indoor environmental measurements within their actual operational context—from the proper selection of monitored parameters to integration with equipment, documentation, and other operational processes. The result is not just graphs, but information that can be put to practical use.